Quotation and contact form | Back to product overview
Measurement of illumination with MAVOLUX 5032
![]() |
|
The MAVOLUX 5032
The MAVOLUX 5032 is an easy-to-handle and a high precision measuring device to determine exactly the level of illumination in the unit lux (lx) or footcandle (fc). It enables you to monitor the quality of light sources such as street lighting, lighting of working environments or public buildings, sports facilities or parks, and also the production of luminaires and lamps. A luminance attachment, available as optional accessory, expands the MAVOLUX by the measurement of luminance in candela per square meter (cd/m2) or footLambert. All important types of light can be measured with high precision. The light sensor is color corrected, i.e. ists spectral responsitivity has been matched to that of the human eye V(λ), therefore it is not necessary to apply correction factors. Suitable cosine correction has been integrated in the light sensor probe, so the oblique incident light will be measured accurately.
![]() |
![]() |
![]() |
Measurement according to DIN 5032
The accuracy of V(λ) matching to the human eye is the main difference between the two types MAVOLUX 5032C and MAVOLUX5032B. MAVOLUX 5032C complies with the accuracy class C for illuminance meters of of the Standard Specifications DIN 5032 (German Institute for Standardization DIN), Part 7 (CIE 69), MAVOLUX 5032B complies with class B. High intensity of light such as daylight or headlights can be measured with both MAVOLUX types without applying any additional accessories. Additionally the MAVOLUX 5032B has been expanded by a decade having a initial sensitivity of 0.01 lux within the lowest measuring range, in such a way as to enable it to measure extremely low light intensities, such as emergency lighting.
![]() |
The MAVOLUX brings along with it an autorange implementation, which automatically selects the best suited measurement range. Alternatively by using the function keys you can manually browse up or down through the measurement ranges. A temporary result buffer enables to hold the measured value for reading at a later date. Furthermore the instruments are provided with a measurement data memory of 100 locations, which can be read and processed with the device or the standard software for PC supplied with the meters. |
Optional accessory for MAVOLUX 5032
Luminance adapter |
Adapter disk for |
Calculating disk |
gLUx Evaluation software
The evaluation software gLux enables to measure at a specified intervall and measuring unit and to list or chart these measured values. Measurement values can be saved as .txt-file, so that the result can be evaluated using a data base or a spreadsheet application. The setup of the device can also be performed by the gLux software. By attaching the measuring device to your PC using the USB interface, it can be energized by the interface for permanent operation. The software supports installation on windows 98SE and downwards compatible systems. Older versions of windows don't support the USB interface.
gLux features additional functions to adjust weighting factors and measured variables, measurement ranges and sampling intervals to continuous measurements. Furthermore gLux offers the rendition of a test pattern with the densities of the SMPTE color bars for acceptance inspections and constancy tests according to IEC 61223-2-5.
The language of the user interface of gLux, german, english, spanish or french, can be chosen by the user on start of the program.
Data communication and
evaluation of the measured
values with gLux
Technical specifications
Sensor:
- Light sensor silicon photo diode with V(λ) filter
Classification
- MAVOLUX 5032 C USB - Class C according to DIN 5032, Part 7 (CIE 69)
- MAVOLUX 5032 B USB - Class B according to DIN 5032, Part 7 (CIE 69)
Characteristics Mavolux 5032C
| Measurement range | Resolution in lx |
Resolution in fc |
||
| in Lux (lx) | in footcandle (fc) | |||
| I. | 0.1 ... 199.9 | 0.01 ... 19.99 | 0.1 | 0.01 |
| II. | 1 ... 1999 | 0.1 ... 199.9 | 1 | 0.1 |
| III. | 10 ... 19900 | 1 ... 1999 | 10 | 1 |
| IV. | 100 ... 199000 | 10 ... 19990 | 100 | 10 |
Characteristics Mavolux 5032B
| Measurement range | Resolution in lx |
Resolution in fc |
||
| in Lux (lx) | in footcandle (fc) | |||
| I. | 0.01 ... 19.99 | 0.001 ... 1999 | 0.01 | 0.001 |
| II. | 0.1 ... 199.9 | 0.01 ... 19.99 | 0.1 | 0.01 |
| III. | 1 ... 1999 | 0.1 ... 199.9 | 1 | 0.1 |
| IV. | 10 ... 19900 | 1 ... 1999 | 10 | 1 |
| V. | 100 ... 199000 | 10 ... 19990 | 100 | 10 |
Measuring rate
- 2 samples per second
Display:
- LCD display 50 mm x 25 mm
- Read-out 7 segments, 3 1/2 digits, 13 mm
- Number of digits: 3 1/2 digits
- Overload signal "OL" in the display
Memory for measurement values
- 100 memory locations, display indication "FLL" = memory full
Interface:
- USB 1.1
Power supply
- Battery: one 1.5V AA alkaline - manganese cell size AA (IEC LR6) or suitable rechargeable battery
- Battery life approx. 45 hours continuous operation with alkaline - manganese battery
- Automatic display of battery symbol when battery drops below 1.0V
- Connected to a PC the power is supplied by the PC via the USB cable to the MAVOLUX
Housing:
- Plastics
Weights and dimensions
- Dimensions Measuring instrument: 65 x 120 x 19 mm (ohne Koffer)
- Probe: 31 x 105 x 30 mm
- Weight Measuring instrument and probe approx. 200g without battery
- Light sensor Light sensitive surface of the diffuser: diameter approx. 20 mm
- Cable length approx. 1,5 m
Electromagnetic compatibility (EMC)
The MAVOLUX meets the specifications 89/336/EWG dt. 01.01.1996
Delivery contents:
- Mavolux 5032 C USB (GOL110) - Class C according to DIN 5032, Part 7, with carrying case, battery, standard software on CD-ROM, USB connecting cable, instruction manual
- Mavolux 5032 B USB (GOL111) - Class B according to DIN 5032, Part 7, with carrying case, battery, standard software on CD-ROM, USB connecting cable, instruction manual
Available accessory:
- Luminance Attachment cd/m² and fL (GOL115)
- Adapter disk for contact measurements (GOL117)
- Calculator Calculating disk (GOL235)
- Cable length for an extra charge:
uncoiled, 3 m,5 m or 10 m, on delivery of the measuring instrument (GOL230, GOL231, GOL232) - Calibration certificate, on delivery of the measuring instrument (GOL240)
Subject to technical alterations